Abstract

Nowadays, there is an increasing necessity to determine the concentration of different substances in the environment in low concentrations, as more and more attention is paid to environmental pollution. This work is devoted to the comparison of main characteristics of high-frequency electrodeless light sources with different fillings for their use in high precision atomic absorption analysers.

The spectral line intensities and profiles were studied in special design light sources, manufactured at Institute of Atomic Physics and Spectroscopy, with arsenic, mercury and thallium filling. Special attention is devoted to the UV lines of 193.7 nm and 197.2 nm of As, 276.8 nm, 377.6 nm of Tl and 253.7 nm of Hg spectral lines. The intensities and profiles were measured by means of a Fourier transform spectrometer.

The deconvolution procedure was implemented to obtain the real form of emitted profiles for further analysis, since in the case of low –pressure or cold plasma, the instrumental function is on the same order that experimental profile and it has to be taken into account. The instrumental function can distort the real spectral line shape significantly, for example, it changes the width of the spectral line that leads to the uncertainties in the determination of such important plasma parameters like temperature. The instrumental function can conceal a detailed structure of the spectral line, like the dip in the line center caused by the self-absorption (self-reversal) and characterizing the radiation trapping.

The integrated areas, values of self-absorption, and other parameters were obtained and compared for all fillings as a function of working regimes.

 

Supporting Agencies
The research was partly supported by project „Atomic physics, optical technology and medical physics (LU IAPS)”.

Downloads

Download data is not yet available.

References

A. Ganeev et al., "High-frequency electrodeless discharge lamps for atomic absorption spectrometry" Spectrochemica Acta B: Atomic Spectroscopy, 58, 5, pp.879-889, 2003.

Zorina N., "Deconvolution of the spectral line profiles for the plasma temperature estimation", Nuclear Inst. and Methods in Physics Research A 623,pp.763-765, 2010

Zorina N. et al., "Validity of the deconvolution method for multicomponent spectral lines" J. Phys.: Conf. Ser. 1289 012045, 2019. (doi:10.1088/1742-6596/1289/1/012045)

G.Revalde N. Zorina, A. Skudra, "Multicomponent line profile restoring by means of ill-posed inverse task solution", J. Phys.: Conf. Ser. vol.810(1),012056 ,2017

(doi: 10.1088/1742-6596/810/1/012056)

G. Revalde, N. Zorina, A. Skudra, "Deconvolution of multiple spectral lines shapes by means of Tikhonov’s regularization metode", in Imaging and Applied Optics, OSA Technical Digest (Fourier Transform Spectroscopy, FTS 2013; Arlington, VA; United States; 23-27 June 2013 June 2013) (Optical Society of America, 2013), paper JTu4A.12. (http://dx.doi.org/10.1364/AOPT.2013.JTu4A.12)

G. Revalde et al., "Deconvolution of the line spectra of microsize light sources in the magnetic field", Romanian Reports in Physics, Vol. 66, No. 4, pp. 1099–1109, 2014.( http://rrp.infim.ro/2014_66_4/A17.pdf)

M. Zinge, Z. Gavare, and E. Gosko "Spectroscopic studies of Tl containing high frequency electrodeless lamps", Proc. SPIE 9421, Eighth International Conference on Advanced Optical Materials and Devices (AOMD-8), 94210G (22 October 2014)(https://doi.org/10.1117/12.2083948).

N. Denisova, G. Revalde, A. Skudra, E. Bogans, “Tomographic diagnostics of high-frequency electrodeless lamps in argon–mercury mixtures” , J. Phys. D: Appl. Phys., vol. 39, pp. 1069 – 1077, 2006. (https://doi.org/10.1088/0022-3727/39/6/012 ).

Downloads

Published

2021-06-16

How to Cite

[1]
N. Zorina, A. Skudra, G. Revalde, and Z. Gavare, “COMPARISON OF AS, HG AND TL HIGH-FREQUENCY ELECTRODELESS LAMPS FOR DETECTION OF ENVIRONMENTAL POLLUTION”, ETR, vol. 1, pp. 275–280, Jun. 2021, doi: 10.17770/etr2021vol1.6529.